Electronic load set

el_zateze.jpgElectronic load set coded EZ2-MA is designed to discharge batteries when testing their capacities. With the test terminated, the measured values are kept in memory and can be uploaded to a PC computer for subsequent processing and plotting the discharge diagrams.

The loading kit consists of EZ2-MA, the control unit, and EZ2, the power units. The units are constructed as plug-in modules of the standard widths - 19" 5U (according to IEC 297-1); the modules are interconnected using cables with error-proof connectors and pairs of copper ribbons used to link the power busbars together. As a standard, the kit is delivered installed in a 19" distribution cabinet with glazed door and perforated back panel. The cables run inside a floor duct enter the cabinet through an opening in the cabinet's bottom. Alternatively, the individual modules can be attached into an installation rack and operated in an arbitrary configuration.

A selector switch available in the control unit can be used to alternate between two permanently connected batteries - this arrangement allows the batteries to be measured without any need for re-connecting the cabinet. The unit can be controlled from ART4000A, a stand-alone control terminal, capable of governing the test in compliance with a preselected program; displaying and archiving the measured values; and configuring all major parameters of the test to be performed. The control unit can be associated with differently sized banks of power units so as to offer the different voltages and discharge currents required for the batteries being tested.

The power units are designed as versatile, able to provide for a wide range of voltages and currents. Their task is to convert electricity into heat as the control unit may command.

The cooling air is sucked in through lateral grids and when heated up by the cooling action it is fanned out of the unit through the perforated back panel. Each unit is fitted with its own protection device and an inbuilt regulator capable of limiting the power, extending fault signals and providing thermal protection.

Technical data

Control terminal

Load
  input 2x 240VDC
  output 240VDC / 80A
Power supply 230VAC / 50Hz / 500VA
Covering IP20 in switchgear with all power units
IP00 without the front panel
Dimensions 19"  5U  482,6 x 221,5 x 420mm 
Weigh 27kg

Power unit

Load
  Max. power 2400W
  Max. voltage 240VDC
  Max. current 200A (při U=12VDC)
Power supply 230VAC / 50Hz / 50VA
Actuation 24VDC
Covering IP20 in switchgear wiht all power units
IP00 without the front panel
Dimensions 19"  5U  482,6 x 221,5 x 420mm
Weigh 23,5kg

Switchgear

Load 2 x 240VDC  /  50A
Power supply 230VAC / 50Hz / 500VA
Covering IP20
Dimensions 600 x 600 x 2200mm
Weigh 270Kg (max.)